Manual vacuum aspirator (MVA)
A 60-mL plastic syringe that acts as a manual vacuum reservoir, connected to a thin, flexible cannula (Karman cannula) of various calibers that is inserted into the uterine cavity.
How it is used
It empties the contents of the uterine cavity in cases of incomplete miscarriage, first-trimester spontaneous pregnancy loss, or early induced abortion, without requiring general anesthesia or electrical power.
Clinical tip
Confirm that the syringe is holding its vacuum (plunger not sliding back) before inserting the cannula into the uterus, since loss of negative pressure is the most common cause of an incomplete aspiration.